5. Auto-close setting.
6.Photo beam setting.
Special function introduction and application.
1.o/s/c Terminal
2.Connection of photo beam/swich control.
Press 'UP' button and hold on until the LED displays '-'.
Press 'up' button once, the auto-close time will increase 1
minute, the maximum time is 9 minutes. Press 'down' button
the auto-close time decrease 1 minute. The auto-close
function will be turned off when LED displays 0. Press 'SET'
button to confirm.
Press 'DOWN' button and hold on until the LED displays'11',
press 'UP' button the LED displays 'H', photo beam function
is available. Press 'DOWN' button the LED displays '11' to
cancel this function. When setting is finished, press 'SET' to
confirm. When connecting pulsed quantity control infrared
sensor, wiring. When infrared sensor is controlled by switch
value, wiring. Notice: Close the photo beam function when you
don't use photo beam sensor.
Connecting a external button between "GND" y "PB" you
can operate the door on the o/s/c sequence.
If you connect a external receiver you can see the picture
in the left.
You can connect the photo beam like the
picture.