Descargar Imprimir esta página

Stiebel Eltron DHB-E 13-2 Operación E Instalación página 9

Calentador instantáneo de confort con regulación electrónica

Publicidad

Idiomas disponibles

Idiomas disponibles

iNSTallaTiON
installation
Preparing the power cable
160
30
1 Installation service
f Prepare the power cable.
f
Fitting the wall mounting bracket
f Mark out the holes for drilling using the installation template.
f
If the appliance is to be installed with water connections on
finished walls, also mark out a fixing hole in the lower part
of the template.
f Drill the holes and secure the wall mounting bracket with
f
2 screws and 2 rawl plugs (screws and rawl plugs are not
part of the standard delivery).
f Fit the wall mounting bracket.
f
Making the water connection
Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
f Seal and insert the twin connectors.
f
www.stiebel-eltron.com
1
1 DHW with tee
2 Gasket
3 Cold water with 3-way ball shut-off valve
4 Strainer
5 Flow limiter or plastic profile washer (see chapter "Installa-
tion / Water installation / Flow rate")
f Secure the tee and 3-way ball shut-off valve, each with a flat
f
gasket, to the twin connector.
!
Installing the appliance
f For easier installation, push the cable grommet of the upper
f
electrical connection into the back panel from behind.
f Remove the transport plugs from the water connections.
f
f Remove the fixing toggle from the upper part of the back
f
panel.
f Route the power cable through the cable grommet from
f
behind until the power cable rests against the cable sheath.
Align the power cable.
Enlarge the hole in the cable grommet if the cross-section of
the power cable is > 6 mm².
f Push the appliance over the threaded stud of the wall mount-
f
ing bracket, so that it breaks through the soft seal. If neces-
sary, use a screwdriver.
f Push the fixing toggle on to the threaded stud of the wall
f
mounting bracket.
f Push the back panel firmly against the wall. Lock the fixing
f
toggle by turning it 90° clockwise.
2
2
1
3
24
5 Nm
5
4
Material losses
Never use the 3-way ball shut-off valve in the cold water
inlet to reduce the flow rate.
DHB-E |
9