After the limit stops have been set, you can also set up to two intermediate stopping points (see
attachment "M").
1. Run the system until reaching the position for the first intermediate stopping point
2. Press button "1" on the motor control panel for 5 seconds
3. The corresponding LED will flash to indicate that the control has been received
If you want to set a second intermediate stopping point (not mandatory)
4. Activate the system up to the position where you wish to set the second intermediate stopping
point
5. Press button "2" on the motor control panel for 5 seconds
6. The corresponding LED will flash to indicate that the control has been received
If the intermediate stopping points are set, when the system is run it will reach the first stopping point
in sequence. If you want to open or close the curtain completely, the control (whether from the button or from
the radio control) must be held for 4 seconds (the "RESET" Led on the motor control panel goes out for a
fraction of a second to signal that the command has been received).
By following the above-described procedure, you can change the intermediate stopping points at any
time without having to change the limit stops. To eliminate the intermediate stopping points, simultaneously
press buttons "1" and "2" on the motor control panel for 4 seconds (the corresponding LEDs will flash once to
indicate that the intermediate stopping points have been cancelled).
To control the Garden 451 by radio it must be assigned to a remote control. To perform this operation
carry out the following procedure (see attachment "L" fig "3L").
1. Put the transmitter into the association mode.
Consult the technical manual for the transmitter being used.
2. Press the R. F. button on the motor control panel for 5 seconds (one flash of the "R. F." LED on
the motor control panel confirms that the association procedure has been carried out correctly)
Setting intermediate stopping points
Assigning an R. F. radio receiver