Descargar Imprimir esta página

Mottura GARDEN 451 Manual De Instrucciones, Uso Y Mantenimiento página 12

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
FAULT
The system does not move
The system does not stop
at the correct position
System blocks after
several consecutive
activations
Power requirement: 110-220 V / 60-50 Hz
Input: 55 W
Sliding velocity: 15 cm/s
Radio frequency chip reception frequency: 868 MHz - 915 MHz
Single control with SINGLE button
Simultaneous control with GROUP button
Manufactured to EU standards
Dimensions: 52 mm x 90 mm x 270 mm
Weight: 1,3 Kg
Troubleshooting
POSSIBLE CAUSE
Limit stops incorrectly set
Incorrect wiring
No electrical power
Faulty motor unit.
R. F. association not
carried out
Limit stops incorrectly set
Obstructions in the curtain
work space
The power supply has
reached the heat protection
threshold
Technical Characteristics
5
REMEDY
Set the limit stops
Check and correct the wiring by following
the instructions in this manual
Restore electrical power
Request replacement of the motor unit.
Carry out the association procedure
Set the limit stops
Remove obstructions
Let the power supply cool for a few
minutes and try again.

Publicidad

loading