EN
TECHNICAL DATA SHEET
Working air pressure
Working temperature
Air consumption
Compatible oils
Pneumatic system pipes
Aerial Noise
Acoustic radiation pressure measured: 60 dBA
Tests carried out in conformity with the standards ISO/R 1680 - 1970. Instrument: LARSON DAVIS 800 B PRECISION ANALYSER
PHONOMETER in conformity with the standards IEC 804 E 651 class 1 set with a Larson Davis Ca 250 114/b 250 Hz calibrator
before and at the end of the measurements.
Measurements and dimensions - YAK 415/R
All manuals and user guides at all-guides.com
8 > 10 bar
116 > 145 psi
-20°C > +50°C
-4°F > 122°F
600 nl/min
ATF Dexron IID
Rilsan ø 6x4 mm
Weight
Max. stroke
1st stage capacity
2nd stage capacity
3rd stage capacity
4th stage capacity
5th stage capacity
80 Kg
176 lb
399 mm
15.7 in
70 t
77 ton (short)
43 t
47 ton (short)
23 t
25 ton (short)
13 t
14 ton (short)
-
1004 mm
A
39.5 in
399 mm
B
15.7 in
150 mm
C
5.9 in
1422 mm
D
56 in
344 mm
E
13.5 in
17