►►6.2. RESETTING THE HEATER:
en
In the models with automatic "RESET", switch
the heater off and back on again (SEE FIG.
it
5-4).
de
►►6.3. SWITCHING THE HEATER OFF:
es
DO NOT PULL THE PLUG OUT UNTIL THE
COOLING CYCLE HAS TOTALLY ENDED.
fr
►6.3.1. Take the "ON/OFF" switch to the "OFF"
nl
(O) position (SEE FIG. 5).
►6.3.2. Disconnect the heater from the mains
pt
electricity (SEE FIG. 6).
da
7. REGULATING THE PRESSURE
fi
OF THE COMPRESSOR (Contact the
technical service center)
no
(SEE FIG. 7)
THE COMPRESSOR PRESSURE MAY HAVE
sv
TO BE RESTORED WITH WEAR OF THE
pl
HEATER.
►7.1. Use the "TECHNICAL DATA TABLE" to
ru
identify the correct pressure (Bar - PSI - kPa)
of your heater.
cs
►7.2. Remove the screw/cap of the manometer
hu
connection (A).
►7.3. Assemble the manometer (not supplied,
sl
see "ACCESSORIES").
►7.4. Switch the heater on.
tr
►7.5. Act on the regulation screw by turning it
hr
clockwise to increase the pressure and anti-
clockwise to decrease it (B).
lt
►7.6. Remove the manometer and restore the
screw/cap (A).
lv
8. CLEANING THE TANK FILTER
et
(SEE FIG. 8)
ro
DEPENDING ON THE QUALITY OF THE
FUEL THAT IS USED, THE TANK FILTER
sk
MAY HAVE TO BE CLEANED.
bg
►8.1. Remove the cap (A) from the tank.
►8.2. Extract the filter (B) from the tank.
uk
►8.3. Clean the filter (B) with clean fuel, paying
attention not to damage it.
bs
►8.4. Re-mount the filter (B) in the tank.
el
►8.5. Close the cap (A).
zh
9. PRESERVATION AND
TRANSPORT
I ORDER TO KEEP AND/OR TRANSPORTAR
THE HEATER IN THE BEST WAY, STHE
FOLLOWING
PROCEDURE
FOLLOWED.
►9.1. Empty the fuel tank (some models have
a draining cap on the bottom of the tank. In
this case, remove the drain cap and empty
the fuel).
►9.2. If the presence of residues is noted, pour
clean fuel into the tank and drain off again.
►9.3. Close the tank cap and/or the draining
cap and dispose of the fuel appropriately
according to the Standards in force.
►9.4. In order to keep the heater in the best
way possible, it must be kept on a level
surface to prevent the escape of fuel and in
a dry place away from any possible external
threats.
10. ROOM THERMOSTAT
►►10.1. MODELS PRE-SET FOR REMOTE
ROOM THERMOSTAT:
(SEE FIG. 9)
For models preset for remote room thermostat,
remove the cover connected to the heater
(A), connect the thermostat (B) (optional) and
set the desired room temperature. The room
thermostat completely turns off the heater once
the set temperature has been reached. If the
temperature drops below the set temperature,
the heater will automatically turn itself on again.
►►10.2. MODELS WITH ROOM
THERMOSTAT INSTALLED ON THE
CONTROL PANEL:
(SEE FIG. 10)
For models with room thermostat installed on
the control panel, when the knob (B) is turned
the desired temperature starts flashing on the
display (A) for a few seconds, after which the
display shows the room temperature. When the
knob (B) is turned completely to the right, the
display (A) shows "CH", after which the heater
works continuously.
►►10.3. MODELS PRE-SET FOR REMOTE
ROOM THERMOSTAT AND ROOM
THERMOSTAT INSTALLED ON THE
CONTROL PANEL:
(SEE FIG. 9-10)
For models preset for remote room thermostat
and room thermostat installed on the control
panel, remove the cover connected to the
heater (SEE A FIG. 9) and connect the
thermostat (SEE B FIG. 9) (optional). For
correct heater operation, completely turn the
MUST
BE
knob to the right (SEE B FIG. 10), the display
(SEE A FIG. 10) shows "CH", after which set
the desired temperature on the remote room
thermostat.