EP-44SIP(H) WEBSERVER
3.3.1.2. SIP Proxy and Registrar 
 
 
Use SIP Proxy: Enable or disable the option to set if a proxy server redirects the packets to the SIP 
server.  
Use SIP Registrar: Enable or disable the option to set directly the IP of the SIP server. 
Registrar IP address or Host Name: Defines the address of the SIP server. 
Register Port: Defines the remote UDP/TCP/TLS SIP port for server' SIP messages. The valid numeric 
range is from 1024 to 65535 and the default value is 5060. 
Registration Expires: Defines the maximum time between registrations. 
Registration Failed Expires: Time interval between a failure in registration and the next solicitation. 
Use SIP Outbound Proxy: Enable or disable the option to set an outbound proxy server to redirect 
the packets to the SIP server. 
Outbound Proxy IP address or Host Name: Defines the address of the outbound proxy server. 
Outbound Proxy Port: Defines the remote UDP/TCP/TLS SIP port for outbound proxy SIP messages. 
The valid numeric range is from 1024 to 65535 and the default value is 5060. 
Use  Redundant  Outbound  Proxy:  Enable  or  disable  the  use  a  redundant  outbound  proxy.  This 
feature  allows  the  configuration  of  a  backup  SIP  proxy  server  to  increase  QoS  stability.  If  the 
primary  proxy  does  not  respond  to  SIP  signaling  messages,  device  will  switch  to  the  redundant 
server without the user noticing any connectivity failure or malfunction. 
Redundant Proxy mode: Select if redundant proxy work in Asymmetric or Symmetric mode. 
Asymmetric  mode:  The  primary  proxy  is  assigned  a  higher  priority  for  registration  than  the 
redundant  proxy.  Once  the  unit  is  registered  to  the  primary  proxy,  it  sends  keep‐alive  messages 
(using SIP OPTIONS messages) to the primary proxy. If the primary proxy does not respond, the unit 
registers to the redundant proxy, but continues sending keep‐alive messages to the primary proxy. 
If  the  primary  proxy  responds  to  these  keep‐alive  messages,  the  unit  re‐registers  to  the  primary 
proxy. 
Symmetric  mode:  Both  proxies  are  assigned  the  same  priority  for  registration.  Once  the  unit  is 
registered to a proxy, it sends keep‐alive messages to this proxy. The phone switches proxies only 
once the proxy to which it has registered, does not respond. 
 