3.3.1.3. SIP Timers 
 
 
The  SIP  timer  service  allows  SIP  applications  to  schedule  and  manage  timers  and  receive 
notifications when timers expire. Timers are events that can be scheduled to run once at a specific 
time, or to repeat at configurable intervals. Normally these parameters are not modified. 
 
Retransmission Timer T1: The valid numeric range is 100 to 60000 and the default value is 500. T1 
is the time interval (in ms) between the first transmission of a SIP message and the answer of the 
same message (RTT round‐trip time established in RFC 3261). 
Retransmission Timer T2: The valid numeric range is 4000 to 60000 and the default value is 4000. 
T2 is the maximum interval (in ms) between SIP message retransmissions (according to RFC 3261). 
Retransmission Timer T4: The valid range is 5000 o 60000 and the default value is 5000. T4 is the 
maximum time that a message could stay in network (TTL) according to RFC 3261. 
INVITE  Timer:  The  SIP  INVITE  timer  according  to  RFC  3261  and  the  valid  numeric  range  is  0  to 
65535. The default number is 32000. 
Session‐Expires:  Establish the time (in seconds) in which the call will be timed out if a successful 
INVITE transaction does not occur. The valid numeric range is 0 to 65535. The typical value is 1800. 
Min‐SE:  The  minimum  value  for  the  session  interval.  The  valid  numeric  range  is  0  to  65535. 
Normally it is set to 90. 
 
Configure the SIP timer parameters and then click Submit, but normally these parameters are left 
unchanged. 
 