EP-44SIP(H) WEBSERVER
 
4.4. Remote Management 
Allow to set the integration by TR‐069 and/or Json and enable/disable the telnet connection. 
4.4.1. TR‐069 
 
 
Activate: Allows disable/enable the TR‐069 protocol. The TR‐069 enables automatic configuration, 
management  and  monitoring  of  Customer  Premises  Equipment  (CPE)  connected  to  an  Internet 
Protocol (IP) network. 
 
Set the TR‐069 and then click Submit. 
4.4.2. Telnet 
 
 
Activate: Allows disable/enable the Telnet protocol. Telnet is only used to access another machine 
remotely for the exchange of information. 
 
Set the telnet and then click Submit. 