Use this button to go one step back.
button
•
Open window protection cannot start when the heater is in fan mode.
It can only start up when appliance in heating mode or in set
temperature mode.
•
Press the open window detection button to start or stop the open
window detection mode.
•
Temperature detection will start after 1 minute.
•
For 10 minutes in a cycle the temperature will be detected every 5
minutes. If the temperature is <8°C than the detection start checks
Open
window
point temperature the appliance will start heating. If the temperature
detection
is >8°C than the detection start checks point temperature the
appliance will stop heating and go into the standby mode.
•
When the 10-minute cycle is finished, the appliance stops heating,
alarm sounds 5 times, the fan operates for 30 seconds and then the
heater will go into standby.
•
Press the window detection button again to begin the next cycle.
•
Press the timer button several times to set the timer as follows. 1
hour, 2 hours, 3 hours... 8 hours.
Timer
•
The timer function can't be used when the week timer is active.
OK
•
Use this button to confirm actions.
button
•
Use this button to cancel the temperature settings or the week timer
mode.
Cancel
Notes:
•
To turn the unit off, press the on/off button again.
•
The fan keeps on working for about 30 seconds to cool down the heater inside
(when having used heating).
•
Maximum temperature is 51°C, the device will shut down automatically if a
temperature of 51°C is detected.
•
The heater is protected against overheating. This will switch off the heater
automatically in case of overheating due to total or partial obstruction of the grids.
In this case, unplug the appliance and wait for about 30 minutes to cool down. After
that remove the object that is obstructing the grids.