Duty cycle
Model
Range
P 3355
0,1...99,9 % 0,1%
Pulse width: >100 µs,< 100 ms
Frequency: 5Hz-150kHz
Sensitivity: <0,5V
P 3360
0,1...99,9 %
4-20mA%
-25...125%
Pulse width: >100 µs,< 100 ms
Frequency: 5Hz-150kHz
Sensitivity: <0,5V
Overload protection:
Temperature
Model
Range
P 3355
-20 ... +760°C
-4...+1400°F
P 3360
-50...+1000°C
-58...+1832°F
Overload protection:
Temperature Accuracy :
Resolution Accuracy
1,2% rdg. +2 dgt.
rms
0,01%
0,01%
0 mA = -25%; 4 mA = 0 %;
20 mA = 100 %, 24 mA = 125 %
rms
600 V DC/AC
Resolution Accuracy
1°C
1°F
1°C
1°F
600 V DC/AC
Probe accuracy not included.
47
+/- 1,2% rdg. +2 dgt.
+/-50 dgt.
rms
3,0% rdg. + 3,0°C
3,0% rdg. + 3,0°F.
1,0% rdg. + 2,5°C
1,0% rdg. + 4,5°F
rms