Descargar Imprimir esta página

Franke AQFT0021 Instrucciones De Montaje Y Uso página 6

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
11. Function
Water flow
11.1 Pull the lever upwards.
• The water will flow.
11.2 Push the lever downwards.
• The water stops flowing.
Temperature selection
12. Maintenance and care
The fitting must be checked and maintained at regular intervals depending on the
water quality and in accordance with the local conditions, and rules and regulations
applicable at the site.
Maintain the following components:
• Aerator (see
• Filters (see
• Non-return valve (see
Use suitable cleaning agents which are not harmful to the fitting in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.
Remove the fitting
For some maintenance tasks, the fitting must be removed.
12.1 Close the water supply.
12.2 Disconnect the fitting.
12.3 Remove the grub screw (c) from the fitting.
12.4 Remove the fitting (a), using the guide sockets (b).
13. Replacing the filters
13.1 Remove the fitting (see
13.2 Replace the filters (a).
Important!
Note the installation position of the filters.
13.3 Reassemble in reverse order.
6
chapter
15.)
chapter
13.)
chapter
chapter
12.).
14.)

Publicidad

loading

Este manual también es adecuado para:

2030017102