OTHER FEATURES
BUCKET FULL LIGHT
The "Full" indicator light will be illuminated when the
bucket is full and ready to be emptied or if the bucket
was not put back in place correctly.
AUTO DEFROST
The unit will automatically enter auto defrost mode
when frost/ice builds up on the evaporator coils. The
compressor will cycle off, and the fan will continue to
run until the frost disappears. During this operation, the
"Auto Defrost" indicator light will be illuminated.
AUTO SHUTOFF
The dehumidifier shuts off when the bucket is full or when
the bucket is removed or is not replaced in the proper
position. The compressor will also automatically shut off
when the desired humidity level is reached. The fan will
continue to operate for an additional three minutes.
AUTO RESTART
In the event of an unexpected power interruption, the
unit will automatically restart with the previous function
setting once the power is restored.
REMOVING THE COLLECTED WATER
USING THE BUCKET
• If the unit is off, and the bucket is full, the "Full"
indicator light will illuminate.
• If the unit is on, and the bucket is full, the
compressor and fan will turn off. Then, the "Full"
indicator light will illuminate, and the LED display will
P2
show code
.
EMPTY AND REINSERT THE BUCKET
• Grip the left and right bucket handles securely, and
carefully pull out straight so water does not spill.
Do not place the bucket on the floor because the
bottom of the bucket is uneven, and the water may
EB
spill. Code
will show on the display panel when
the bucket is removed. Empty the water from bucket
into a drain.
• The bucket must be replaced carefully and securely
for the dehumidifier to operate. The code
disappear from the display panel, and unit will
re-start with the last-used settings after the bucket is
returned to its correct position.
PAGE 10 OF 46
OPERATION CONTINUED
1.
2. Hold both sides of the bucket with even strength,
3. Gently push the bucket fully into the unit. Banging
CONTINUOUS DRAINING
Continuous drainage uses gravity to pull the water out
of the unit through a hose. A white screw cap covers
the continuous drain outlet; unscrew it to attach the
continuous drain hose. The drainage outlet hose must
be sealed with the provided cap when not in use.
Failure to tightly seal the cap if drain is not in use will
cause leaking water.
• A small water pan inside the unit is already installed
• Basement floors will always have a slight downward
EB
will
Partially remove the bucket. (See Figure 3)
and completely remove from the unit and pour out
the water. (See Figure 3)
NOTE: When removing the bucket, do not
touch any parts inside the unit. Doing so may
damage the product.
Figure 3
the bucket against anything or failing to push it in
securely may cause the unit not to operate.
on the optional angle to route water out as soon as
the unit creates it. Dehumidifiers are designed to be
used on leveled floors. If the unit is placed on an
unleveled or even slightly forward angle, the water
will run into the bucket as a backup.
slope toward the floor drain. Place the unit so the
back panel is facing the floor drain.
0124 IH-11032