Descargar Imprimir esta página

Uline H-11032 Manual Del Usuario página 9

Deshumidificador de oficina

Publicidad

Idiomas disponibles

Idiomas disponibles

TURBO BUTTON
The TURBO button is to toggle between normal fan
speed and the highest fan speed (turbo).
• Press to select either High or Normal fan speed.
• Set the unit to turbo by pressing the TURBO button
(green light illuminated) for maximum moisture
removal.
• When the desired humidity level has been reached,
press the TURBO button once more (green light will
disappear) to return to normal operation.
TIMER BUTTON
The TIMER button is used in conjunction with the
Humidity Set Control arrow buttons to initiate the
Auto Start/Auto Stop feature.
SETTING THE TIMER
The TIMER button can be used to set a desired on or off
time for the dehumidifier. The on time or off time setting
can only be set in increments of 0.5 hour up to 10 hours
and 1-hour increments from 10 to 24 hours.
NOTE: If the unit is off, the Timer "On" indicator
light will be the first to illuminate.
NOTE: If the dehumidifier is on, the Timer "Off"
indicator light will first illuminate.
NOTE: Toggle between Timer "On" and Timer
"Off" by pressing the TIMER button.
• Press the TIMER button, and the Timer "Off" or "On"
indicator light illuminates. This indicates the
Auto Stop/Auto Start program is initiated.
• Press or hold the button to change the desired
stop/start time by 0.5-hour increments, up to
10 hours, then at 1-hour increments from 10 to 24
hours from the time the feature is set. The control
will count down the time remaining until the
dehumidifier stops/starts.
• Press the TIMER button again, and the Timer "On"
indicator light will illuminate. This indicates the
Auto Start program is initiated.
• Press or hold the button to change the desired start
time by 0.5 hour increments, up to 10 hours, then at
1-hour increments from 10 to 24 hours from the time
the feature is set. The control will count down the
time remaining until the dehumidifier starts.
PAGE 9 OF 46
OPERATION CONTINUED
• When the Timer "On" and Timer "Off" times are set,
• Turning the unit on or off at any time or adjusting the
• If the water bucket is full and the LED display window
HUMIDITY SET CONTROL LEFT/RIGHT BUTTONS
• The Humidity Set Control buttons are used to set the
• The humidity level can be set between 35% RH and
• For drier air, press the button to the desired lower
• For more humid air, press the button to the desired
POWER BUTTON
• Press to turn the dehumidifier on and off.
• Dehumidifier will power on and automatically
LED DISPLAY
Depending on the feature selected, the LED Display
will show the current RH% in the room (35-85%), the
Auto Start/Auto Stop setting (0.0-24 hours) while setting
the timer function, as well as the desired humidity level
setting for the dehumidifier. The accuracy of the relative
humidity reading in the room is +/-5% for humidity levels
between 30-90%.
within the same program sequence, both on and off
indicator lights will illuminate indicating both on and
off times are programmed.
timer setting to 0.0 will cancel the
Auto Start/Auto Stop function.
P2
displays
, the Auto Start/Stop function will also be
canceled.
desired humidity level.
85% RH in 5% increments.
RH% level.
higher RH% level.
NOTE: The machine will not run the compressor
or start dehumidifying area until the room
humidity percentage rises higher than set
percentage.
resume last used settings.
0124 IH-11032

Publicidad

loading

Este manual también es adecuado para:

H-11035