11. Troubleshooting
Fault
Motor does not start
The drive motor
does not start
Motor performance
drops
Unclean cuts
Important! In order to secure the engine and the batteries, these are equipped with a thermal
switch, which switches off when overloaded and automatically switches on again after a coo-
ling phase!
Anl_GP_CM_36_47_52_S_Li_BL_SPK13.indb 30
Anl_GP_CM_36_47_52_S_Li_BL_SPK13.indb 30
GB
Possible Cause
a) Motor terminals disconnected
b) Machine standing in high grass
c) The mower housing is clogged
d) Safety plug is not inserted
e) Battery is not correctly inserted
a) Motor terminals disconnected
b) Machine standing in high grass
c) The mower housing is clogged
d) Safety plug is not inserted
e) Battery is not correctly inserted
f) Thermal cut-out switch has tripped
a) Grass too tall or damp
b) The mower housing is clogged
c) Blade badly worn
d) Battery performance decreasing
a) Blade worn
b) Wrong cutting height
- 30 -
Remedy
a) Have it checked by a customer ser-
vice workshop
b) Start motor on shorter grass or al-
ready mowed area; change cutting
height if necessary
c) Clean housing so that the blade
can run freely
d) Insert the safety plug (see 6.)
e) Remove the battery and reinsert
(see 5.)
a) Have it checked by a customer ser-
vice workshop
b) Start motor on shorter grass or al-
ready mowed area; change cutting
height if necessary
c) Clean housing so that the blade
can run freely
d) Insert the safety plug (see 6.)
e) Remove the battery and reinsert
(see 5.)
f) Let the equipment cool down for at
least 10 minutes
a) Correct the cutting height
b) Clean the housing
c) Replace the blade
d) Check the battery performance
and charge the battery if necessary
(see 5.)
a) Replace or resharpen the blade
b) Correct the cutting depth
05.07.2023 13:14:54
05.07.2023 13:14:54