7. Remove the knockout plates in the back of the unit with snips. (for some models)
8. Place the blower unit back into the opening.
CAUTION:
Do not pull or stretch the blower unit wiring. Make sure the wires are not pinched, and
that they are properly secured.
NOTE:
The blower unit exhaust openings should match exhaust openings on rear of microwave
oven.
9. Secure the blower unit to the microwave with the original screw.
10. Replace the blower plate in the same position as before with the screw. Make sure the
screw is tight.
Back of Microwave
AFTER: Fan Blade
Openings Facing Back
End B
Knockout Plates:
Snip all 4 webs on
each knockout panel
and remove the metal
knockouts for rear airflow.
Please take care to
remove any sharp edges
created from removing
the knockout plates.
Blower Plate
Back of
Microwave
Blower Motor
Screw
EN-38
End A