Descargar Imprimir esta página

Amsta AMCLI090EN Manual De Usuario página 50

Aire acondicionado local móvil

Publicidad

Idiomas disponibles

Idiomas disponibles

Clean and reinstall the air filters: in case of obvious dirt, wash the filters in lukewarm
soapy water, rinse them and dry them before replacing them in its compartment.
Remark : If using the air conditioner in an extremely dusty environment, clean the
air filter every 2 weeks.
• MAINTENANCE AFTER USE:
If you do not plan to use the device for an extended period:
1. Remove the rubber plug from the drain opening (bottom of the unit) to drain the unit.
2. During ½ day and in good weather, run the appliance in VENTILATION mode only so that
it dries inside and prevents it from molding.
3. Switch off and unplug the appliance.
4. Clean the air filter and reinstall it.
5. Remove the air hoses and store them carefully. Close the hole tightly.
6. Always unplug the machine from the power outlet before putting it away.
TECHNICAL SPECIFICATIONS :
Model :
Supply voltage :
Power consumption :
Cooling capacity :
Refrigerant gas:
Type of fuse used:
Discharge pressure:
Suction pressure:
Maximum tolerated pressure:
Protection class:
ENERGY EFFICIENCY CLASS
NOMINAL COOLING CAPACITY (kW)
RATED ABSORBED COOLING CAPACITY (kW), P
NOMINAL ENERGY EFFICIENCY COEFFICIENT,
ENERGY CONSUMPTION (kWh / 60min),
Energy consumption of 1.0kWh for 60 minutes, based on results obtained under standardized test
conditions. The actual energy consumption will depend on the conditions of use and the location of
the device.
AMCLI090EN
220-240V ~ 50 Hz
1005W
2630W
R290 / 170g
T3.15A, AC250V
3.2 MPa
0.7 MPa
3.2 MPa
Class I
BRAND
REFERENCE
P
refrigerated
rated
EER
rated
Q
SD
EER
EN-24
AMSTA
AMCLI090EN
A
2,630
1.005
2.62
1,002

Publicidad