4 Checks prior to operation
4.1 Battery connection (only electrical models with electrical startup)
The battery is provided with a
disconnected
terminal.
connecting the battery, check that the
engine switch is in the "OFF" position.
If
you
have
any
identifying the engine switch, check
chapter
3.1
(panel
identification).
Avoiding
any
unwanted
connect the generator power cables
on the battery terminals:
Negative cable on negative terminal (Black)
Positive terminal on positive terminal. (Red)
Charge cable on charge terminal. (White)
NOTE: Models GUARDIAN S6-SOL and GUARDIAN S6 ATS use Li-ion type
battery, if you ever replace the battery for any reason, be sure to use original
GENERGY Li-ion battery. Never use other type of batteries; the charge system of
these batteries is different to traditional batteries
NOTE: Respect the cable polarities, connect the red cable (+) to the red
terminal (+) of the battery and the black cable (-) to the negative (-) of the battery.
The white charge cable should be connected to the battery charge terminal.
Incorrect connection can damage electrical parts of the equipment and the battery
itself.
NOTE: Extreme precautions so as to not make unwanted contact with the
battery terminals and cables, among them or against a metallic part of the
machine.
Before
TERMINAL
questions
on
components
contacts
44
CHARGE LINE (WHITE WIRE)
-
BATTERY
+
TERMINAL