EN
• No load balancing weight measured by the controller is displayed in configuration tool.
• This completes the enable no load balancing setup.
• To disable no load balancing feature, click the option "Clear no load balancing weight", and save this setting by clicking on "Write settings"
button. Last, no load balancing weight will be set to zero.
• When the settings are saved successfully in the controller, configuration tool notifies the user with message box as shown below:
Interlock
The interlock feature will not allow the handling device to open while it is suspended. This feature can be enabled using the configuration
tool. Once enabled, the yellow lights indicate the user the state of interlocking operation as below:
• Yellow light1, indicates that the part is clamped.
• Yellow light2, indicates that the part is released.
• Yellow light3, indicates that the part is ready to be removed from the controller and load is no longer supported.
Note: Yellow lights status indication for float mode ready is not available when interlocking is enabled.
Steps to Enable/Disable Interlocking
• Using the handle mode, lift the handling device or gripper load to a height where it is clearly suspended in air.
• Connect the controller to laptop with a USB cable.
• Run the configuration tool.
• To enable no interlocking feature, click the option "Set new interlock weight" , and save this setting to the controller by clicking on "Write settings"
button. Configuration tool will indicate the status of write operation with a write successful message box.