• This completes the enable interlocking feature setup.
• To disable no interlock feature, click the option "Clear interlock weight" and save this setting by clicking on "Write settings" button. Last,
interlock weight will be set to zero.
• When the settings are saved successfully in the controller, configuration tool notifies the user with message box as shown below:
Note: The controller does not allow to disable/clear previously set interlock weight when the load weight measured by the controller is more
than the handle weight. Make sure to clear last interlock weight, the handling device should be lowered fully to the ground. Configuration tool
displays below message box when interlock disable is attempted while the load is still suspended in air.
Max Weight/Over Pressure
Controlled pressure within the chamber will prevent fast upward movement if there is a blockage of the load or gripper, or sudden release
of the load. Use this feature to prevent from such occurrence or limit the ZG balancer capacity. Use this field in configuration tool to set the
maximum weight.
47804819_ed3
EN-5