WARNING:
Read and understand all instructions
before using the machine. Failure to follow all instructions
listed below may result in electric shock, fire and/or
serious personal injury.
WARNING:
During use of high pressure cleaners,
aerosols may be formed. Inhalation of aerosols can be
hazardous to health.
WARNING:
High pressure jets can be dangerous
if subject to misuse. The jet must not be directed at
persons, live electrical equipment or the machine itself.
WARNING:
Do not use the machine within range of
persons unless they wear protective clothing.
WARNING:
Do not direct the jet against yourself or
others in order to clean clothes or foot-wear.
WARNING:
Risk of explosion – Do not spray
flammable liquids.
WARNING:
High pressure cleaners shall not be used
by children or untrained personnel.
WARNING:
High pressure hoses, fittings and
couplings are important for the safety of the machine.
WARNING:
Water that has flowed through backflow
preventers is considered to be non-potable.
WARNING:
Do not use the machine if important
parts of the machine are damaged, e.g. safety devices,
high pressure hoses, short pressure gun.
WARNING:
Depending on the application, shielded
nozzles can be used for high pressure cleaning, which
will reduce the emission of hydrous aerosols dramatically.
However, not all applications allow the use of such a
device. If shielded nozzles are not applicable for the
protection against aerosols, a respiratory mask of class
FFP 2 or equivalent may be needed, depending on the
cleaning environment.
This machine is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge. Children should be supervised to ensure
that they do not play with the appliance.
Know how to stop the product and bleed pressure
quickly. Be thoroughly familiar with the controls.
Prevent unintentional starting. Ensure the switch is
in the off-position before connecting to battery pack,
picking up or carrying the appliance. Carrying the
appliance with your finger on the switch or energizing
appliance that has the switch on invites accidents.
Always be aware of the danger of the reaction force
and the sudden torque on the spray assembly when
operating the gun.
8
56V LITHIUM-ION PRESSURE WASHER — HPW2000E
Do not expose the appliance or battery to excessive
temperatures.
Be aware of the risk of terminals of the battery-
operated appliance or battery being short-circuited by
metal objects.
Rechargeable batteries are to be removed from the
appliance before being charged.
Different types of batteries or new and used batteries
are not to be mixed.
Exhausted batteries are to be removed from the
appliance and safely disposed of.
If the appliance is to be stored unused for a long
period, the batteries should be removed.
Do not use non-rechargeable batteries in place of
rechargeable batteries.
Do not use modified or damaged batteries.
Use only with the specified battery packs and
chargers.
Save these instructions. Refer to them frequently and
use them to instruct others who may use this machine.
If you lend someone this machine, lend them these
instructions also to prevent misuse of the product and
possible injury.
SPECIFICATIONS
Voltage
Maximum Rated Pressure
Maximum Rated Flow
(with quick connect lance and
stainless steel wand connected)
Maximum Rated Flow
(with only short pressure gun
connected)
Limited Maximum Pressure for Gun
Limited Maximum Flow for Gun
Weight (without battery pack)
Recommended Operating
Temperature
Recommended Storage Temperature -20°C - 70°C
Measured sound power level L
WA
Sound pressure level at operator's
ear L
PA
56 V
135 Bar
6.5 L/min
9.5 L/min
250 Bar
30 L/min
16.8 kg
5°C - 40°C
84 dB(A)
K=1.8 dB(A)
72 dB(A)
K=3 dB(A)