WORKING CONDITION INDICATOR
Power Button LED Indicator
Solid green
Solid green
Green light gradually
fading in and out
Orange light gradually
fading in and out
Green and orange lights
alternately fading in
and out
Flashing green, 1 flash
every second
Solid red for 1 minute,
then shuts off.
Flashing red for 1
minute, 1 flash every 0.5
seconds, then shuts off.
Flashing red for 1
minute, 1 flash every
second
NOTE:
Under any work condition (charging or discharging), the LED Indicator on battery pack will behave as described here:
-
For EGO battery packs BA1400, BA2800, and BA4200, the LED flashes GREEN, RED and ORANGE alternately.
-
For EGO battery packs BA1400T, BA2242T, BA2800T, BA3360T, BA4200T, BA5600T, and BA6720T, last LED flashes
GREEN and the former LEDs shine solid GREEN, OR LEDs shine solid GREEN according to battery capacity. The
battery will refresh LEDs every 1-2 minutes to update the real-time fuel gauge.
-
For EGO battery packs BA2240T, LEDs will remain off.
Working Condition
Standby
Powering a device connected
to AC output port, and the AC
output port power is less than
10W.
Powering connected devices
Charging the battery pack
Powering connected devices
AND charging the battery pack.
Low battery voltage.
The power inverter or battery
pack is overheated.
The power inverter may be
overloaded or short circuited.
Other electronics error.
56 VOLT POWER INVERTER — PAD5000E
Action
n/a
n/a
n/a
n/a
n/a
See "LOW BATTERY PACK CHARGE
PROTECTION" below.
Allow the unit to cool down, then
restart the inverter. See "OVER TEM-
PERATURE PROTECTION" below.
Disconnect device from the AC out-
put port, see "OVERLOAD OR SHORT
CIRCUIT PROTECTION" below.
Disconnect your device and
reconnect it again, if the same
fault reoccurs, please contact EGO