Astralpool PRO-ELYO INVERTER 13 Manual Del Usuario página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 169
NOTE
Water Flow Switch:
It is equipped with a flow switch for protecting the HP unit running with adequate water flow rate .It will
turn on when the pool pump runs and shut it off when the pump shuts off.
Time delay - The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid
excessive contact wear. The unit will restart automatically after this time delay expires. Even a brief power
interruption will trigger this time delay and prevent the unit from restarting immediately. Additional power
interruptions during this delay period do not affect the 3-minute duration of the delay.
4.5 Condensation
The air drawn into the heat pump is strongly cooled by the operation of the heat pump for heating the pool
water, which may cause condensation on the fins of the evaporator.
NOTE
The amount of condensation may be as much as several liters per hour at high relative humidity. This
is sometimes mistakenly regarded as a water leak.
4.6 Pressure gauge display (R410A)
Examine the pressure gauge which indicates the refrigerant gas pressure of the unit, the below table
shows the normal value of the gas pressure (R410A) when the machine is in power off or running
conditions.
Unit Condition
Ambient (℃)
Water temp (℃)
Pressure gauge (Mpa)
Unit Condition
Ambient (℃)
Water temp (℃)
Pressure gauge (Mpa)
Power Off
-5~5
5~15
/
/
0.68~0.93
0.93~1.25
Running
/
/
10~15
15~20
20~25
1.3~1.8
1.5~1.9
1.6~2.3
10
15~25
25~35
/
/
1.25~1.64
1.64~2.1
/
/
/
25~30
30~35
1.9~2.8
2.1~3.5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pro-elyo inverter 21Pro-elyo inverter 35

Tabla de contenido