Submerged installation
● Operation with the pre-filter fitted.
1. Push the pre-filter over the suction unit and
fasten the filter using the bayonet closure.
2. Place the unit in the water at the desired
position.
● Ensure that the unit is fully submerged.
Maximum installation depth:13.3 ft.
Dry installation
1. Bolt the suction unit on and turn the priming opening
to an optimum position for priming and connecting
the suction hose.
2. Connect the suction hose to the suction unit.
● Always position the unit below the water line to
prevent dry running and the intake of air when
switching on and operating the unit. Risk of
damage!
● Never connect the unit to a water line.
● Install the unit so that it is not exposed to direct sun
radiation (max. 104 ºF - 40 ºC).
Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
!
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
Important:
● The unit turns on automatically when power connection is established.
1. Turning on: Connect the unit to the outlet.
2. Switching off: Unplug the unit from the outlet.
● The amount of water flowing through is adjustable by the flow through regulator
Attention! The installed temperature sensor automatically turns the pump off, if it is overloaded. The
!
pump automatically switches on again once the motor has cooled down. Risk of accident!
4
- English -

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Prior to reaching into the water, disconnect the power supply to all units used in the water.
• Disconnect the power plug prior to carrying out work on the unit.
Important!
This units housing can not be opened for inspection. Opening the housing voids
!
warranty and can cause Death or severe injury. Follow cleaning instructions for routine cleaning.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
• In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can be
used. Subsequently, clean the pump thoroughly using clear water.
• Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
Storage/Winterization
The unit is frost resistant to -4°F (- 20 °C). Should you store the unit outside of the pond, clean it thoroughly with a soft
brush and water, check it for damage, then store completely submerged in a container of water. . Do not submerge the
power plug in water!
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority.

Spare parts

The use of original parts from OASE ensures continued safe and reliable operation of the unit. Please visit our website for
spare parts drawings and spare parts. www.oase-livingwater.com
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.
Troubleshooting
Never open the housing! Only allow a qualified electrician to replace the power cable!
Issue
Cause
Unit does not run
No mains voltage
Rotor blocked
Insufficient fountain height
regulator closed too far
filter housing soiled
air in the hose
rotor soiled
hose blocked or defective
hose kinked
rotor worn
filter clogged
Unit switches off after a
Water temperature too high
short period of operation
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
Solution
check mains voltage
rinse the vane from the front
set regulator
clean filter housing
vent hoses
clean
clean hose or replace
check hose and replace if necessary
replace rotor
clean filter
Note maximum water temperature of
95°F (+35°C)