MAINTENANCE AND CLEANING

N O T E
Recommendation on regular cleaning:
• Clean the unit as required but at least
twice per year.
• Do not use aggressive cleaning agents
or chemical solutions as they could at-
tack the housing or impair the function
of the unit.
• Recommended cleaning agent for re-
moving stubborn limescale deposits:
– Pump cleaning agent PumpClean
from OASE.
– Vinegar- and chlorine-free household
cleaning agent.
• After cleaning, thoroughly rinse all parts
in clean water.
Cleaning the non-return valve
Sand can block the non-return valve of the
pump so that it cannot close properly. The
non-return valve has to be cleaned.
Prerequisite:
• The pressure hose and adapter have
been dismantled.
ProMax Pressure Automatic 5500/5,
6000/8, Well Automatic 6000/8
How to proceed:
 F
1. Remove the screws.
2. Carefully remove the cover.
– The ball of the vent valve will fall out.
Ensure that you do not lose the ball.
3. Pull out the non-return valve.
4. Thoroughly clean the non-return valve
with clean water.
5. Reassemble the parts in the reverse or-
der.
6. Prior to installing, allow the pump to
convey clear water for a few minutes
(e.g. in a basin) to completely remove
any sand residue. (→ Installation and
connection)
ProMax Pressure Well Automatic
3000/15
How to proceed:
 G
1. Use suitable locking ring pliers to re-
move the locking ring.
2. Pull out the non-return valve.
3. Thoroughly clean the non-return valve
with clean water.
4. Reassemble the parts in the reverse or-
der.
5. Prior to installing, allow the pump to
convey clear water for a few minutes
(e.g. in a basin) to completely remove
any sand residue. (→ Installation and
connection)

WEAR PARTS

The following components are wear parts
and may only be replaced by the OASE
Service.
• Impeller unit
DE
EN
FR
NL
ES
PT
IT
DA
NO
SV
FI
HU
PL
CS
SK
SL
HR
RO
BG
UK
RU
CN
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Promax pressure automatic 6000/8Promax pressure well automatic 3000/15Pressure well automatic 6000/8

Tabla de contenido