取扱説明書
5.2
UL 認証に関する注意事項
ja
5.3
接続に関する注意事項
116
取 扱 説 明 書 | GTB20
UL approval
表 2: UL approval
G20 products with DC voltage supply and
with:
•
connector
•
cable
•
cable with connector
UL:
The device shall be supplied from an
isolating transformer having a secondary
overcurrent protective device that complies
with UL 248 to be installed in the field
rated either:
a) max 5 amps for voltages 0 V ~ 20 V (0
V ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 V ~ 30 V
(28.3 V ~ 42.4 V peak)
Alternatively, they can be supplied from
a Class 2 voltage supply.
UL Environmental Rating: Enclosure type 1
For use in NFPA 79 Applications only
G20 products with AC voltage supply and
with:
•
cable
•
cable with connector
UL:
UL Environmental Rating: Enclosure type 1
For use in NFPA 79 Applications only
G20 products with DC and AC/DC voltage
supply and with:
•
terminal chamber: Gxx20x-QK and
Gxx20x-QL
UL:
For use in NFPA 79 Applications only
センサの接続は必ず無電圧状態で行ってください。接続タイプに応じて、以下の情
報に注意するようにしてください:
–
オスコネクタ接続: ピン割り当て
–
ケーブル: ワイヤの色
–
端子接続:ピン割り当ておよび以下の各ポイント
端子接続:
1.
リアカバーの M3 ネジを緩めて、リアカバーを取り外します。
2.
横方向または縦方向に正しい位置となるよう、3/8 インチ MPT(管用オネジ)
継手、スペーサー、ラバーシール(下図参照)およびリアカバーの開口部分に
電圧フリー電源ケーブルを通します。
3.
表 3 および表 4
に従って 3/8 インチ MPT(管用オネジ)を締め付けます。
4.
それぞれのワイヤを端子ブロックに接続し、 0.4~0.5 Nm のトルクで固定しま
す(参照 表 5, ページ 118 および表
9) 。
記載内容につきましては予告なしに変更する場合がございますのであらかじめご了承ください。
8026846.1K1S/2024-02-08 | SICK