If the feeding gas pressure is
different or variable from the
required one, you must install an
appropriate pressure adjuster,
which is not supplied with the
product. If needed, it must be
ordered separately from the local
After Sales Service Provider, refer
to the Service chapter. The
pressure adjuster must be fitted
on gas supply pipe, in compliance
with the rules of the force.
The rating plate is located below the surface
of the casing.
Adjusting flame level
When you install the hob, it is necessary to
check the minimum flame setting:
1. Turn the gas tap to the maximum
position and ignite.
2. Set the gas tap to the minimum flame
position and turn the control knob from
minimum to maximum several times. If
the flame is unstable or extinguished,
follow the procedure further.
3. Re-ignite the burner and set to
minimum.
4. Remove the control knob and the gasket.
Warning! Pay attention not to
damage the gasket. Do not
use sharp tool to remove it.
5. To adjust, use a thin bladed screwdriver
and turn the adjustment screw until the
flame is steady and does not extinguish
when the knob is turned from minimum
to maximum, and vice versa (see
following picture).
6. Repeat this procedure for all burners.
7. Reassemble the gasket and the knobs.
Warning! Make sure to place
the gasket exactly in the
original position.
Warning! If the appliance is
connected to liquid gas (G31
propane or G30 butane), the
regulation screw must be
fastened as tightly as possible.
If the gasket is damaged, it must
be ordered from the After Sales
Service Provider.