ENGLISH
Gas connection
Warning! Refer to Safety
chapters.
Caution! Information for
authorised installer only.
Connection to main pipe
Warning! This appliance is not
connected to a combustion
products evacuation device.
The installation must be compliant with the
current local regulations. The connection of
the cooktop to the gas pipe network or gas
cylinder must be made by means of a rigid
copper or steel pipe with fittings complying
with local regulations, or by means of a
continuous-surface stainless steel hose
complying with local regulations. The
maximum length of the hose is 2 linear
metres.
If there is a problem with the
pipe, do not repair it yourself.
Contact the local After Sales
Service Provider. Refer to the
Service chapter.
The connection must be installed correctly
and fixed into the hob connection pipe.
Otherwise, gas may leak from the
connection pipe.
Warning! When you finish the
installation, check the sealing and
pipe fixing. To check the
installation, use soapy water. Do
not use the flame.
Gas setting conversion
You can check the parameters of
adjustment setting for this
appliance on the rating plate.
Refer to the Technical data
chapter.
You can use this model with
natural gas. However, you can
convert it for use with other
gases, providing the correct
injectors.
For more information on injector
replacement, refer to the Technical data
chapter.
Warning! Conversion or
replacement can only be
performed by a authorised
technician.
To replace injectors:
1. Remove pan support.
2. Remove burner cap and crown.
3. Using a socket spanner 7, unscrew and
remove the injectors, and replace them
with the ones required for the type of
gas in use.
4. Reassemble the parts, following the
same procedure backwards.
Place the label with relevant
information for new type of gas
close to the supply pipe before
sealing the appliance. If the
appliance is already sealed please
stick it directly on the user
manual booklet, after Technical
data chapter, and close to the
rating plate drawing.
You can find this label in package
supplied with appliance.
37