Description
Elements on the display
During the tightening procedure, the current torque
is shown on the display. The displays are
dependent on the set measuring mode. Information
on the current settings is additionally displayed.
No.
Explanation
1
Set torque or
name of the sequence plan
2
Set function mode:
Click (C)
Peak (P)
Track (T)
3
Currently present torque
4
Malfunction/message symbol
(When processing a sequence plan, the
number of threaded connections already
completed and the total number of threaded
connections to be carried out are displayed
here, e.g. 2/5)
5
Function-specific symbols (see following
table)
12
No.
Explanation
6
Charge indicator (only visible on switching
on or if the rechargeable battery's state of
charge is insufficient)
Symbol
Explanation
Charge indicator
Right-hand tightening
Left-hand tightening
Taring process running
Taring process ended
Move upwards, increase values
Move downwards, reduce values
Administrator password required
An error has occurred, see
page 40
Measured values, status information and other
information are shown on the display depending on
the operating state. The torque display flashes as
long as the measured value lies outside of the
calibrated measuring range. As soon as the
measured value lies in the calibrated range, the
current measured value is displayed constantly.
Example for TORSIOTRONIC
The measured value display flashes as long as the
measured value is less than 10 % of the nominal
value (1 N·m).
type 1000:
®