Description
Technical data
Measuring range
[cN‧m]
[N‧m]
[ft‧lb]
[in‧lb]
[in‧oz]
Output square
[mm]
Length [mm]
Width [mm]
Height [mm]
Weight [g]
Tolerances
Lower tolerance limit
Upper tolerance limit
Triggering processes
Alert
Display
Interface
Memory
Sequences
14
TT 120
TT 300
12–120
30–300
0.12–1.2
0.3–3
0.08–0.885
0.2–2.3
1.06–10.7
2.6–26.6
16.9–169.9
42–425
6.3 (1/4")
6.3 (1/4")
317
317
41.5
41.5
47.4
47.4
567
569
Adjustable:
No tolerance
Relative tolerance
Absolute tolerance
Tolerance window
Max. 100 % of the target value, but at least 80 % of the initial measuring
range value
Max. 100 % of the target value, but max. 120 % of the measuring range
end value
Click (C)
Peak (P)
Track (T)
Adjustable: 50–100 % of the set value
Self-illuminating colour display
Micro USB 2.0, STAHLWILLE protocol
25 sequence plans with 200 fastening operations, up to 2500 fastening
processes
TT 600
TT 1000
60–600
100–1000
0.6–6
1–10
0.4–4.45
0.7–7.3
5.3–53.1
8.8–88.5
84.5–849.5
141–1417
6.3 (1/4")
6.3 (1/4")
317
317
41.5
41.5
47.4
47.4
571
573