Descargar Imprimir esta página

geberit FLOWFIT Instrucciones De Uso página 32

Ocultar thumbs Ver también para FLOWFIT:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 79
EN
Maintenance
Maintenance regulations for Geberit pressing
jaws
These Geberit FlowFit pressing jaws are low-maintenance and do
not need to be tested by authorised repair shops if they are used as
intended. However, pressing jaws still require maintenance.
Pressing jaws that are not maintained, or are not professionally
maintained, can cause accidents and injuries.
It is essential to observe the maintenance intervals and
maintenance work outlined below:
Maintenance
interval
Regularly, before
use, at the start of
the working day
32
Maintenance work
▶ Check the Geberit FlowFit pressing jaw for
externally visible defects such as damage,
material cracks, patches of rust and other
signs of wear. Replace the pressing jaw if
defects are present.
▶ Remove any deposits on the pressing tips.
▶ Spray the pressing tips with a lubricant
recommended by Geberit and clean with a
cloth.
▶ Test whether the jaw levers can move
easily. Check for dirt between the jaw
levers. If necessary, clean the jaw levers
and move them several times until they are
able to move easily.
9007212209767563 © 01-2024
972.178.00.0(00)

Publicidad

loading