At the end of charging with the
electronic battery charger, the bat-
tery does not provide the correct
voltage (about 2.14 V per element
without load) and only one or a few
elements are found to be dischar-
ged when tested with a hydrometer
(battery models only)
The electrolyte in the battery is tur-
bid (battery models only)
one or more elements are damaged
the battery has reached the end of the charging/
discharging cycles declared by the manufactu-
rer
the battery has been charged with too high a
current
the battery has been charged beyond the limit
suggested by the Manufacturer
GB
replace the damaged elements if pos-
sible.
For 6 or 12 V single block batteries, re-
place the entire battery
replace the battery
replace the battery
replace the battery
35