5.4 Alarms
3 alarms can happen :
Join
experience
Cutting/bevelling motor current cunsomption has been
too high during cycle. Cycle has been stopped in order
to protect motor. Check first blade or carbide tip wear
and replace if needed. Then check that you use a
correct motor speed and advance speed. It may be
necessary to reduce advance speed.
A problem happens on the rotation motor of the SAEX.
This can be caused by:
Shut down SAEX, wait several secondes and switch
on. If problem is still active, wait several minutes for
motor cooling. If problem is still active, contact
AXXAIR.
Cutting / bevelling motor has been swithed off during
cycle. Check motor cable and plug. Check turning part
of the cable.
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
-
Too much effort on rotation
-
Motor failure