The device is designed to be connected to a protected outlet at all times. The EasyChem Double must not be disconnected
unless the pool equipment is undergoing maintenance or the pool is to be closed (wintering).
Assuming that the chemical balance of the water is within the recommended ranges, the device can be started up.
6a. Description of the home screen and defaults parameters
Default parameters
n
Item
1
Language
2
Set Point value
3
Dosing method
4
OFA Time
5
Calibration
6
Circulation pump
7
Dosing type
8
IN Freq.
9
Flow Input
10
Power ON Delay
11
Flow Delay
To restore the default parameters, follow the steps below:
Power off the device unit
Keep
and
The unit will display Init.default
Select the unit to reset - WiFi module or dosing system
Press
or
Select Yes and press
EasyChem Double and Plug version | pH · ORP
6. SETUP AND OPERATION
Value
EN
7.4 pH
Acid (pH)
OFF
Full
ON
PROP; Relay Aux1, Aux2, Aux3 are disabled
OFF
NO (normally open) (Reed Sensor)
OFF
OFF
pressed and power on the unit
to select Yes or no
to restore the default parameters.
Only use spare parts supplied by Hayward brands ®
Display
700 mV
Low (Redox)
Page 9 on 27
Button to decrease the value
Escape button
Enter button
Button to increase the value
Measure alarm ranges default parameters
n
Item
1
Temp. Measure min
2
Temp. Measure Max
3
pH Measure
min
4
pH Measure
Max
5
ORP Measure min
6
ORP Measure Max
Limits
+ 10°C
+ 38°C
6 pH
8.0 pH
+450 mV
+850 mV