Scroll through the menu using
6b3. Advanced menu
The Advanced menu consists of the following sub-menus:
• Language: Set language menu (EN, IT, ES, DE, FR)
• Circulating Pump: Enable/Disable input signal from pool circulation pump
High voltage 230Vac.
• In Freq.: Flow rate function measure, Enable/Disable input frequency
signal from water meter pulse sender, set Pulse/Liter or Liter/Pulse.
• Calib. pH: Double ore Single point and Reference calibration, Double point
7pH and 4pH, Single point 7pH, reference pH value.
• Calib. ORP: Single point and Reference calibration, Single point 465 mV,
reference ORP mV value.
• Calib. Temp: Reference calibration by external hand held controller.
• Dosing Type pH: Proportional, Timed, On/Off, Off (disable pump)
• Dosing Type ORP: Proportional, Timed, On/Off, Off (disable pump)
• Aux Relay: Set AUX1: pH or disable; AUX2: ORP or Disable
• Password: Set value to enable password of setting menu. (0000 disable)
• Reset Cal: Menu to reset the last Calibration value, and reload the factory
settings
• Reset all Param.: Menu to reset all parameter and reload the factory
settings
• Control Panel: Menu to show the input raw signal, pH in mV raw signal,
ORP in mV raw signal, Temperature in Ohm raw signal.
• Reed: set logic sensor NO/ NC (normally open/close)
• P.On Delay: Power ON delay function is a countdown timer Off...60'
to delay dosing actions when switch on the device. During this period
the system wait the chemical measure stabilizing the dosing pump are
disable.
• Flow Delay: Flow delay function is a countdown timer Off...60' to delay
dosing actions when the flow rate will be restable, and during this time
the chemical measure will be stabilizing the dosing pump are disable.
EasyChem Double and Plug version | pH · ORP
, select the item and confirm with
Only use spare parts supplied by Hayward brands ®
ALARM MIN
.
ALARM MAX
TIME ON
TIME OFF
Main Menu
ADVANCED
ADVANCED MENU
LANGUAGE
ADVANCED MENU
CIRCULATING PUMP
ADVANCED MENU
IN FREQ
ADVANCED MENU
CALIB. pH
ADVANCED MENU
CALIB. ORP
ADVANCED MENU
CALIB. TEMP
ADVANCED MENU
DOSING TYPE PH
ADVANCED MENU
DOSING TYPE ORP
Page 12 on 27
600mV
800mV
180"
360"