Hayward EASY-CH-DPHRXG Manual Del Usuario página 20

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
EN
Alarm
Level
*only active measures
Out of Range measure
OFA First Alarm
(time >70%)
OFA Second Alarm
(time 100%)
Flow Rate
Calibration Function
System Error
Alarm measure (*1)
(*1 Measure alarm ranges default parameters)
n
Item
1
Temp. Measure min
2
Temp. Measure Max
3
pH Measure
min
4
pH Measure
Max
5
ORP Measure min
6
ORP Measure Max
EasyChem Double and Plug version | pH · ORP
8. ALARMS
Display
Actions to do
- Restore Product tank
Lev Low
- Replace or check the measure probe
ALARM BAND
- Restore measure
OFA_1 blinking
- Press
seconds to reset
OFA_2
- Press
seconds to reset
- Restore Flow Rate
Flow
- Restore Probe or Buff er solution and repeat calibration
CALIBRATION ERR
procedure
ParameterS error
- Press
- Broken Unit
- Adjust the chemical concentration
High Measure
Low Measure
Limits
+ 10°C
+ 38°C
6 pH
8.0 pH
+450 mV
+850 mV
Only use spare parts supplied by Hayward brands ®
for 3 seconds to reset or press
for 3 seconds to reset or press
to restore Default parameter
Page 19 on 27
for 5
for 5