ENGLISH
-
To remove the filter, press on the tabs as shown in Figure 9 and pull it out.
Carbon filter
This type of filter has activated carbon and purifies air and absorbs cooking odours. The
activated carbon becomes saturated after a period of time, which will reduce the adsorption
capacity of the filter. The carbon filter cannot be washed nor cleaned in any way. When its
service life comes to an end you must replace it with a new one.
-
It is recommended to check the condition of carbon filters regularly, at least two or three
times a year. Its replacement will depend on how the kitchen hood is used, as well as the
daily operating time.
-
In case of very frequent frying, shorten the time interval for checking and/or replacing the
carbon filters.
Installing the carbon filters
Remove the protective metal filters.
1.
2.
The carbon filters are located on both sides of the motor. Insert and turn the filters, until
they are firmly in place.
3.
To replace the carbon filter, proceed in reverse order.
The carbon filter must not be exposed to heat.
4.
Fig. 2 10:
A: Closed
B: Opened
C: Opened
D: Closed
Carbon filter diameter:
Article No 02859/02860/02861 > 132 mm
Article No 02862 > 176 mm
Replacing the light bulb/lamp
Please note:
-
The light bulb must be replaced by the official Cecotec Technical Support Service or
similarly qualified technicians.
-
Always disconnect the power supply before performing any operation on the appliance.
When handling the bulb, make sure that it has cooled down completely before any direct
contact with your hands.
-
When handling the bulbs, hold them with a cloth or gloves to prevent sweat from coming
into contact with the bulb, as this may reduce the bulb life.
Note:
BOLERO FLUX TLM 603500 WHITE A / BOLERO FLUX TLM 603500 BLACK A/
54
BOLERO FLUX TLM 603500 INOX A/ BOLERO FLUX TLM 606500 INOX A
-
Before changing the light bulb, make sure that the appliance is switched off and unplugged.
-
Protect yourself from danger when changing the light bulb, e.g., by wearing gloves.
6. TROUBLESHOOTING
Fault
Cause
The indicator light is
The kitchen hood is
on, but the motor does
obstructed
not work
The condenser is damaged
Motor is jammed or bearing
damaged
Motor is burnt or gives off a
bad smell
Neither the light bulb
In addition to the above, check the following:
nor the motor work
The light bulb has blown
Power cable is loose
Grease falls out of the
The filters are very dirty
aluminium filters
The kitchen hood
The fan is damaged, causing
vibrates
the kitchen hood to vibrate
when extracting air.
The engine is not securely
fastened
The kitchen hood is not
securely fastened
BOLERO FLUX TLM 603500 WHITE A / BOLERO FLUX TLM 603500 BLACK A/
BOLERO FLUX TLM 603500 INOX A/ BOLERO FLUX TLM 606500 INOX A
ENGLISH
Solution
Remove what is obstructing the
hood
Please contact the official Cecotec
Technical Support Service to
replace the condenser.
Please contact the official Cecotec
Technical Support Service to
replace the motor.
Please contact the official Cecotec
Technical Support Service to
replace the motor.
Please contact the official Cecotec
Technical Support Service to
replace the light bulb.
Please contact the official Cecotec
Technical Support Service to
connect the cables according to the
wiring diagram.
Clean or replace the aluminium
filters immediately
Please contact the official Cecotec
Technical Support Service to
replace the fan.
Fix the engine correctly
Fix the kitchen hood correctly
55