g
eneral safety regulations
Thank you for having chosen this product. Your new electro-mechanical
barrier has been produced to a high level of quality and reliability
that guarantees efficiency and safety for a long period of time. The
attachments to this booklet contain all the necessary information to
assemble your barrier and to safeguard your security.
All our products are constructed according to regulations in force.
During assembly and maintenance operations use only original spare
parts. Avoid accidents by taking the necessary preventative and
prudent actions.
i
Mportant
It is forbidden to carry out any assembly, repair or adjustment
operations by non qualified personnel and all necessary precautions
must be taken to avoid accidents, such as disconnecting the power
supply (including any buffer batteries present). All moving parts must
be fitted with protection guards.
ATTENTION: Any use not foreseen in this instruction manual and/or
any arbitrary modifications made to this product or its components,
frees DASPI from all responsibility for damage or harm to persons,
animals or property.
Keep this manual and the attached technical file of the installation in
a safe place, known to all personnel so it is available for future use.
Dispose of all packaging materials after installation (boxes, plastic,
polystyrene, etc.) according to regulations in force, paying special
attention to plastic bags that can be extremely dangerous if children
are in the vicinity.
S
m
ecurity
ecHaniSm
diStance
in mouVement
ProDuCt tyPe
The ELTRA 400 barrier has been designed and constructed to
open barrier arms up to 4 meters in length. DASPI does not
assume any responsibility for other use than the intended use
of the ELTRA 400 barrier.
ATTENTION: The ELTRA 400 barrier is not equipped with
a mechanical clutch and therefore when installed must be
connected to a special DASPI control unit or to a control unit
equipped with an electronic clutch.
uSe oF tHe MeCHanISM
Important safety instructions
Attention, for personnel safety it is of vital importance to carry
out the following instructions.
Keep these instructions in a safe place. Do not allow children
to play with the fixed or remote controls of the gate. Place the
remote controls out of the reach of children.
As the mechanism can be controlled nearby or at a distance
using push buttons or remote controls it is indispensable that
the efficiency of all safety devices be checked frequently. We
recommend periodical checks (every six months) by qualified
personnel to adjust the electronic clutch. To adjust this protection
device, see the paragraph "Electronic clutch adjustment" in the
instruction manual of the electronic control unit.
PrelIMInary CHeCkS
• Read carefully all parts of this manual.
• Check that the product was not damaged during
transportation.
• Check that the electrical plant conforms to the characteristics
englISH
d
e
o not inStaLL tHe
Lectric SHocK
automation in pLace fuLL
of expLoSiVe moiStureS
Instruct all personnel involved with operating the mechanism about
the commands and safety systems installed on the plant.
This product cannot be installed in an explosive atmosphere.
M
aintenance
Disconnect the power supply before carrying out any maintenance
operations. To correctly maintain the plant where the ELTRA 400
barrier is installed, proceed as follows:
Periodically clean the photocell optics.
Charge qualified personnel to adjust the electronic clutch (see relative
paragraph of the electronic control unit installation manual).
If any malfunction occurs, notify qualified personnel.
d
eMolition
Demolition must take place according to regulations in force. Recycled
materials must be separated by type (copper, aluminium, plastic,
electrical parts, etc.). No materials considered dangerous to the
handling personnel are present.
d
isMantling
Proceed as follows to dismantle or transport the mechanism to
another location:
Turn off the power supply and disconnect the electrical plant.
Disassemble the control panel and all the components of the
installation.
If some components are damaged or cannot be removed, substitute
the components.
u
Se
tHe gLoVeS
required by the gear motor.
• Check that an adequate grounding plant exists and that all
metallic parts are connected to this plant.
• We remind you that the mechanism facilitates use of the
barrier and does not resolve problems due to defects, bad
installation or lack of maintenance to the barrier.
luBrICatIon
The ELTRA 400 barriers are supplied with permanent grease
lubrication
InStallatIon
Important safety instructions for installation.
Warning: A bad installation can cause a great deal of damage or
harm. Scrupulously follow all installation instructions.
ATTENTION: For any reason whatsoever never disassemble the
barrier arm when it is in a horizontal position
ATTENTION: For any reason whatsoever never carry out an
emergency or manual manoeuvre if the barrier arm is not
assembled
ATTENTION: Do not release the motor when it's working
For correct commissioning of the ELTRA 400 barriers, proceed
as follows:
Locate the point inside the property where the ELTRA 400 barrier
will be installed (figure 1).
Construct a solid concrete base with the dimensions illustrated
on figure 1; provide a passage for the sheath "G" of the power
cables and system controls.
Before the concrete sets, position the "Ps" plate (OPTIONAL) well
down into the concrete making sure that the plate is correctly
u
K
Se gLaSSeS
eep tHe protection
for WeLding
carter

Publicidad