Prohibited connections
Recommendations of the power supply connection to the electricity network
• Use the power transformer supplied.
• Connect the 230Vac input of the transformer to the electrical network, protecting it with a 2A disconnecting circuit.
• Connect the 24Vdc output of the transformer to the Tempus Air RS4 using a sheathed cable type H05RN-F 2x0.75mm²
• Place the transformer and circuit assembly in a Class II electrical box.
1.2 Battery connection
• Connect the battery.
1.3 Reassembly the Tempus Air RS4
• Adjust the length of the cable by pulling on it.
• Fit the parts together by applying strong pressure
and lock the 2 parts.
• Tighten the anti-traction.
• Set the switch to ON
During the first installation it is
necessary to charge the Tempus Air RS4
battery for 24 hours with 230VAC power
before turning it ON.
Upon startup, the Tempus Air RS4 LEDs
will flash red. Pair the Tempus Air RS4, in
the MyToroTempus App via Bluetooth, to
your MyToroTempus account, following
STEP 2. (We remind you that the SIM Card must be activated). The LEDs will turn green
for one hour after pairing to indicate that the product is operational.
• Adjust the cable.
Close the Tempus Air RS4
• Close the lower and upper parts using the locking pictograms
Toro Tempus Air RS4
3