Poor
cooling
effect,
no
cooling
There
is
loud noise
and
vibration
8)If the machine malfunctions and alarms, please contact a professional to
find out the cause before using it.
iv.Common faults and troubleshooting methods
v.Packing List
No.
board connection wire
falls off
5.
The
switch
controller is broken
6. Compressor overload
protection
1. Use directly under
sunlight
2. Is the air grille in and
out
of
the
blocked?
3.
The
temperature is too high
4. The condenser is too
dirty
5.
The
compressor,
capacitor and protector
are broken.
6. Refrigerant leakage
1. The machine is placed
unevenly
2. The fan blade touches
other accessories
3. Machine parts are
loose
item
restore it
or
5. Replace the switch or the
controller is broken.
6. After power outage, it will
automatically recover for
30-60 minutes and then
turn on again.
1. Change the placement
location
2. Leave more than 200mm
machine
of space for air inlet and
outlet.
ambient
3. Change the placement
location
4. Clean the condenser
5. Replace the compressor,
capacitor or protector
6. Check for leaks, repair
leaks, and refill refrigerant
1. Place it stably
2. Calibrate the fan blades
3. Reinstall
quantity
- 6 -