Troubleshooting
8.3 Error codes and flashing sequences
Flashing code
Short orange flashes
1x long green lighting
1x long red flash
Brief orange flashing
(every 10 s)
Brief orange glow (after
green or red receipt mes-
sage)
Alternating long and
short orange flashing
6x long red flashes
1x orange, 1x green light-
ing (after inserting batter-
ies)
Meaning
Radio transmission/send
attempt/data transmis-
sion
Transmission confirmed
Transmission failed or
duty cycle limit reached
Pairing mode active
Batteries empty
Device software updating
(OTAU)
Device defective
Test display
Solution
Wait until the transmis-
sion is completed.
You can continue opera-
tion.
Try again
(see „8.2 Duty cycle" on
page
25).
Enter the last four digits
of the device serial num-
ber to confirm
(see „6.1
Pairing" on page
19).
Replace the device bat-
teries
(see „7 Changing
the batteries" on page
24).
Wait until the update is
completed.
Please see your app for
error message or contact
your retailer.
You can continue once
the test display has
stopped.