Consult the dealer or an experienced
radio/TV technician for help.
▶ Electronic Cell Protection
(ECP)
The lithium ion battery is protected against
deep discharging by the "Electronic Cell
Protection (ECP)". When the battery is
Functional Description and Specifications
IG. 1
2
3
Charger input voltage
Battery Charging current
AMPShare
batteries
18V 2.0Ah
18V 3.0Ah
18V 4.0Ah
18V 5.0Ah
18V 6.0Ah
SAVE THESE INSTRUCTIONS
1
4
120 V
4.0A
Approximate charging time
to capacity
80%
100%
24 min
35 min
36 min
50 min
48 min
65 min
60 min
70 min
72 min
95 min
empty, the tool is switched off by means of
a protective circuit.
The battery is supplied partially charged.
Completely charge the battery before using
your cordless power tool for the first time.
The lithium ion battery can be charged at
any time, without reducing its service life.