This water heater should be installed inside or in enclosed spaces, because it does not
require ventilation.
The heater must be located away from flammable materials or places with strong
magnetic fields.
If it is installed outside, the heater requires protection against the rain, preferably a
roof at a minimum of 80 cm from the heater cover. If the heater is not protected from
the rain, this could damage the equipment and the electrical installation, rendering the
warranty void.
The heater must be perfectly fixed to avoid movement during earthquakes and/or
tremors, in order to prevent it falling from its position. It must also be protected by a
roof or niche to avoid direct contact with the rain.
Remove the 2 screws that fasten the front cover on the water heater
(see Fig. 3) and remove the front cover.
The surface where the heater will be installed must be solid and secure. DO NOT install
the unit over connections or electrical boxes.
Place the heater on the surface where it will be installed. Check that it is leveled.
Install the heater on the wall with the 4 screws and 4 wall plugs provided at the marked
points (see Fig. 4). The non-use of these may cause damage to the installation.
FIG. 2
Do not install the heater in
reverse or lateral position