25 / EN
ELECTRICAL SPECIFICATIONS TABLE:
Type
Power (W)
Supply voltage (VAC)
Phase
Amperage (A)
Recommended breaker (A)
Required cable diameter
* For commercial use, we recommend 3 phases
Cable most be 100% copper.
This heater must be installed according to the following indications regarding the
presence of:
•
Humidity: do not install the appliance in humid environments.
•
Ice: do not install the appliance in environments with a probability of temperatures
dropping to critical levels with a risk of ice formation.
•
Sun rays: do not expose the appliance directly to solar rays, not even through glass.
•
Dust/vapors/gases: do not install the appliance in notably aggressive environments,
such as those with acid vapors, dusts, or saturated gas.
•
Electric shock: do not install the appliance directly on electrical lines that are not
protected from voltage fluctuations.
V.- WATER INSTALLATION
The system shall be installed so that the control for adjusting the temperature of the water
in normal use, installed at the outlet of each shower, has priority over any other control for
adjusting the temperature of the water in normal use at any other outlet.
To achieve a good heater installation, verify the type of water supply system you have at your
Open System (with a water tank): to supply water to the heater, an air tube must be installed
at the cold-water inlet.
•
The air tube installation must not be omitted for the cold-water inlet, and we recommend
installing one for the hot water outlet also.
Model
Eleva Pro 15 V2
Electric Instantaneous
15000
220
2*
68
3 x 30 (double pole)
3 x 10 AWG