CRN4500
Item No. 65690
12
OPERATINg ThE NAILER
CONNECTIONS
fittings
Install a female coupler to the hose. The female coupler
will connect to the quick release that fits the tool.
1
1
filter-Regulator-Lubricator
Never connect nailer to pressure that potentially exceeds
150psi.
Filter-regulator-lubricator units supply an optimum
condition for the nailer and extend the nailer life. These
units should always be used.
filter
The filter removes moisture and dirt mixed in
compressed air.
Keep the filter clean by maintaining tool regularly.
2
2
Drain daily.
Regulator
The regulator controls the operating pressure for safe
operation of the nailer.
Inspect the regulator before operation to be sure it
operates properly.
Lubricator
The lubricator supplies an oil mist to the nailer.
Inspect the lubricator before operation to be sure the
supply of lubricant is adequate.
3
If an inline lubricator is not used, a few drops of oil will
3
need to be added to the air inlet before each use.
Air hose
Air hose must have a minimum working pressure rating
of 200psi or 150% of the maximum pressure produced in
the system, whichever is higher.
Interchange Brands Coil Nailers: Operator's Manual