6. Environment conditions:
-
T he BENNING CC 1 is intended for making measurements in dry
environment.
-
M aximum barometric elevation for making measurements: 2000 m,
- O vervoltage category IEC 60664/ IEC 61010, 300 V category III,
600 V category II,
- Contamination degree 2 according to EN 61010-1
-
Protection Class: IP 30 (DIN VDE 0470-1 IEC/ EN 60529)
I P 30 means: Protection against access to dangerous parts and protection
against solid impurities of a diameter > 2.5 mm, (3 - first index). No
protection against water, (0 - second index).
- O perating temperature and relative humidity:
F or operating temperatures from 0 °C to 30 °C: relative humidity less than 80 %
F or operating temperatures from 31 °C to 40 °C: relative humidity less than 75 %
F or operating temperature from 41 °C to 50 °C: relative humidity less than 45 %
-
S torage temperature: The BENNING CC 1 can be stored at any temperature
in the range from 20 °C to + 60 °C ).
7.
Electrical specifications
Note: The measuring precision is specified as the sum of
- a relative fraction of the measured value and
-
a current value in A.
The measurement precision applies at a temperature of 23 °C ± 5 °C and a
relative humidity less than 75 %.
7.1 Alternating current measurement
Measurement
range
400 A
Max. equivalent source resistance: 75 Ω
8. Making measurements with the BENNING CC 1
8.1 Preparations for making measurements
Operate and store the BENNING CC 1 only at the specified storage and
operating temperatures. Avoid continuous insulation.
-
T he nominal voltage and current ratings of the safety measuring
cables included in the scope of delivery correspond to the ratings of the
BENNING CC 1.
-
T he safety measuring cable is securely connected to the BENNING CC 1
and cannot be removed.
-
C heck the insulation of the safety measuring cables. Discard the
BENNING CC 1 immediately if the insulation is damaged.
-
D o not clamp the measuring pliers on a live conductor before the
BENNING CC 1 has not been connected to a multimeter.
S trong sources of interference in the vicinity of the BENNING CC 1 can lead
to unstable readings and measuring errors.
- Do not apply any voltage to the output contacts of the BENNING CC 1.
Do not exceed the maximum permitted voltage with respect to
earth potential! Electrical danger!
The highest voltage, that may be applied to the BENNING CC 1 against ground
potential, is 600 V.
12/ 2005
Measured
value
3 A
30 A
350 A
400 A
BENNING CC 1
Output
Measurement precision
3 mV
30 mV
350 mV
400 mV
± (1,9 % + 0,5 A)
at 50 Hz - 60 Hz
± (3,2 % + 1 A)
at 50 Hz - 60 Hz
7