CLOCK MENU
Date and time adjustment:
Unit operating time band adjustment;
The first field with the wording OFF can be changed to ON in order to enable the time band set.
8
DOMESTIC HOT WATER PRODUCTION
The production of domestic hot water is regulated by means of a set and a settable band, through the digital input ID7 the request is piloted: closing the contact activates
the production of domestic hot water while opening the contact activates the production of water for air conditioning. When the DHW function is active, the integration
resistances are not used.
Attention: If diverter valves are used that create water flow problems, the switchover delay time (set_installer(n10) ) must be used and an external timer (e.g. electro-
mechanical) must be inserted that delays the switchover of the 3-way valve during any defrosting in progress (it must be calibrated to the maximum defrosting time).
In the case of an inverter machine, an additional time of 60" must be added on top of the 5-minute maximum defrost time.