Descargar Imprimir esta página

Behringer 1004 Guía Rápida página 8

Publicidad

14
OSCILLATOR MODULE 1004
OSCILLATOR MODULE 1004 Controls
控制
(CN)
(1) COARSE FREQUENCY –
在低频 (
LFO
) 范围
0.03
32 Hz
内设置频率从
兹, 或在高
15.5 Hz
16 kHz
频 (音频) 范围内从
兹至
取决于
Fine
频率旋钮的设置。
(2) FINE FREQUENCY –
通过±1个八度的因子
调整频率, 可能在任一极端减半或加
倍频率。
(3) ENABLE switch –
打开或关闭振荡器。
(4) RANGE switch –
确定振荡器在低频
/ LFO
(次声
) 频段还是高频 (音频) 频段
操作。
(5) WAVEFORM switches –
通过将相关切换
开关向左移动来使最多
5
种波形参与,
或通过将开关向右移动使反向波形参
与。 中间位置关闭波形。 同时激活多个
开关会产生所有活动波形的平均值。
(6) PW knob –
手动控制脉冲波形的脉冲
宽度。
(7) FM 2 knob –
衰减连接到
FM 2
输入的
信号。
(8) PWM knob
- 调整
PMW
控制输入的调
制深度。
(9) FM 1 knob
- 衰减连接到
FM 1
输入的
信号。
KYBD
3.5 mm TS
(10)
- 通过
电缆连接键盘
或其他外部频率控制。
FM 1/2
(11)
- 连接外部电压以调制频率。
PWM
- 连接外部电压以调制脉冲宽度。
(12)
OUT
3.5 mm TS
- 通过
电缆将振荡器信
(13)
号发送到其他模块。
,
Power Connection
P1
Red Stripe
2
1
10
9
200 mm ± 10
Connect end P1 to the module socket
Connect end P2 to the power supply
The OSCILLATOR MODULE 1004 module comes with the required power cable for connecting to a standard Eurorack power
supply system. Follow these steps to connect power to the module. It is easier to make these connections before the
module has been mounted into a rack case.
1. Turn the power supply or rack case power off and disconnect the power cable.
2. Insert the 16-pin connector on the power cable into the socket on the power supply or rack case. The connector has a tab
that will align with the gap in the socket, so it cannot be inserted incorrectly. If the power supply does not have a keyed
socket, be sure to orient pin 1 (-12 V) with the red stripe on the cable.
3. Insert the 10-pin connector into the socket on the back of the module. The connector has a tab that will align with the
socket for correct orientation.
4. After both ends of the power cable have been securely attached, you may mount the module in a case and turn on the
power supply.
Installation
The necessary screws are included with the module for mounting in a Eurorack case. Connect the power cable
before mounting.
Depending on the rack case, there may be a series of fixed holes spaced 2 HP apart along the length of the case, or a track
that allows individual threaded plates to slide along the length of the case. The free-moving threaded plates allow precise
positioning of the module, but each plate should be positioned in the approximate relation to the mounting holes in your
module before attaching the screws.
Hold the module against the Eurorack rails so that each of the mounting holes are aligned with a threaded rail or threaded
plate. Attach the screws part way to start, which will allow small adjustments to the positioning while you get them all
aligned. After the final position has been established, tighten the screws down.
Quick Start Guide
P2
1
2
HOT USED
15
16
+ 12V
+ 12V
GROUND
GROUND
- 12V
- 12V
15

Publicidad