OPERATION INSTRUCTIONS
1a. Flushing and checking for leaks:
Important: After installation is completed, turn on
the hot and cold water supplies. Check for leaks.
Pull the hose assembly out of the spout and remove
the spray head by unscrewing it from the hose in a
counterclockwise direction. Be sure to hold the end
of the hose down into the sink and turn the faucet to
the warm position where it mixes hot and cold water.
Flush the water lines for one minute. This flushes
away any debris that could cause damage to internal
parts. Check for leaks. Do not lose the gasket (1) in
the hose.
Re-tighten any connections if necessary, but do not
overtighten. Reinstall the spray head by hand tightening
it back onto the spray hose in a clockwise direction.
1b. Turn the handle (1) away from the faucet to the full on
position. Turn the water on by activating the sensor (2)
by waving your hand within 2-3/8 inches of the sensor.
Move handle towards you and away from you, the water
flow pattern can be switched from the hot water to
cold water. If the sensor does not work, then you can
refer to the troubleshooting. If you want to use the
faucet without the sensor feature, then you
can refer to step 4. Then, turning on the water
can be done by moving the handle away from
the faucet to the full on position.
NOTE: As a water saving feature, the water will turn off
automatically after 3 minutes of continuous flow.
2. If it is necessary to remove the quick connector (1),
squeeze the tabs (2) on the quick connector and
then pull down to disconnect.
1a
1
1b
45
2
Squeeze
9
0
3
min.
15
30
Hot
2
1
2
Pull
down
1
1
Cold