Replace the BLADE UNIT into the body.
Turn the POWER SWITCH on.
Make several test cuts in order to make sure the tape will not fall
down from the TAPE OUTLET.
Clean the Sensors
There are two pairs of SENSORS below the TAPE OUTLET.if the
opening is covered by tape residue or debris, the SENSORS will
not detect the presence of tape.
Always keep clean around the SENSORS.
To protect the SENSOR, clean the openings after removing the
BLADE UNIT carefully.
Clean the Body
Put neutral detergent on a damp cloth to clean the body. Do not use
alcohol or solvent to clean the plastic parts.
The buzzer will have a sound then a message will flash and show
on the DISPLAY.
E-02 Blade is Out of Position
A signal shows that the blade is not installed well or machine stops
because of the thickness or hardness of the tape.
Turn the POWER SWITCH off.
Remove the BLADE UNIT by releasing the BLADE UNIT
RELEASINGLEVER then lift the assembly out of the body.
Turn the POWER SWITCH on.
Press the FWD BUTTON and feed -in the tape once, cut the tape
in between the TAPEOUTLET and the BLADE UNIT with
scissors.
Press the REV BUTTON to remove the tape
Clean the BLADE UNIT and lubricate the LOWER BLADE
GUIDE.
Check the lower blade position and replace the BLADE UNIT.
Error Messages